Thursday 1 September 2011

Application Engine Program: PSPAL::Abort: Unexpected Signal Received

When we create an Application Engine program which refers to a State Record, and migrate it to other environment without migrating the State Record, it will get migrated successfully. When we try to run this program on the Batch Server, the following error message will appear.


Record XYZ not defined (108,505)
1341: 1301685557: PSPAL::Abort: Unexpected signal received
1341: 1301685557: PSPAL::Abort: Location: /vob/peopletools/src/pspal/exception_sigaction.cpp:492: RecoverableSignalHandler
1341: 1301685557: PSPAL::Abort: Generating process state report to /xxx/xxx/scripts/LOGS/psae.1341/process_state.txt
1341: 1301685557: PSPAL::Abort: Terminating process now.


In Windows
2564: 1301686035: PSPAL::Abort: Unrecoverable exception received
2564: 1301686035: PSPAL::Abort: Location: E:\pt85010b-retail\peopletools\SRC\pspal\exception_winunhandled.cpp:577: PSPAL::UnhandledExceptionFilter::RecoverableExceptionFilter
2564: 1301686035: PSPAL::Abort: Abort diagnostics generation is currently disabled
2564: 1301686035: PSPAL::Abort: Terminating process now.
PeopleTools 8.50.10 – Application Engine


Record XYZ not defined (108,505)
Message Set Number: 108
Message Number: 505
Message Reason: Record XYZ not defined (108,505)


Solution


Copy the missing AET Record to the target database and its application engine program will work fine.